Jeol jem 2010 manual

The settings can be modified to produce the best images of your samples. Use keyboard and mouse lying on top of gatan computer to log into that computer. Follow the procedures below when you use the jem1400plus tem. Nanoscale fabrication and characterization facility, university of pittsburgh. Temcon double click black stageneutral button to neutralize sample position. Those who have been registered in the previous web site, please make a. Basic stepbystep instructions for jeol 6060lv version 411 general operation 1. The jem2100f is a multipurpose, 200 kv fe field emission analytical electron microscope. If the sem software is not running, start sem software sem main menu icon. Follow the procedures below when you use the jem1400plus. It explains the basic procedures for operating the system. Please refer to section 4 of the for a complete description of all controls, apertures, etc. The labsonda the ufrj epma lab was created in 2010 and is coordinated by dr. The jeol 2010f is a high resolution transmission electron microscope.

Please remember that the following should be used only as a starting point for your particular work. This manual is designed for new users of the jnmeca. With the renewal of this web site, we have a number of renewed contents. Jeol jem1230 operating instructions university of iowa. The microscopy and imaging center is a core user facility supported by the office of the vice president for research. Jeol jem2100f instruction manual 129 pages field emission electron microscope. Jem 2100 manual operation and basic alignment instructions 1. Page 1 instructions jem2100f field emission electron microscope for the proper use of the instrument, be sure to read this instruction manual.

The mic is staffed by research scientists with expertise in transmission electron microscopy, scanning electron microscopy, light microscopy, and supporting instruments therein. Standard operating procedure for the jeol 2010 hrtem. Jeol is a world leader in electron optical equipment and instrumentation for highend scientific and industrial research and development. Jem2100f field emission electron microscope jeol ltd. Key features lattice imaging hrtem elemental identification and mapping edxs and eels electronic state identification and mapping eels magnetic and electronic field mapping electron holography phase and orientation identificationmapping with 1 2 nm resolution diffraction stem automated phase and. Even after you read it, please keep the manual on hand so that you. The fe electron gun feg produces highly stable and bright electron probe that is never achieved with conventional thermionic electron gun. Missouris jeol 1400 is capable of taking images of biological samples, polymers and nanoparticles. This instrument has a lattice image resolution of 0. Jeol jem2000ex tem department of materials science and. This manual contains information regarding the basic operation of this microscope for conventional imaging. Guidelines jem 2010 the jeol 2010 tem is a sensitive instrument and requires delicate, responsible, and properly trained users in order to maintain high quality operation. We have 1 jeol jem2100f manual available for free pdf download. This transmission electron microscope arrived in march 2010 and moved to the mas building in november 2011.

The jem 2000ex has an accelerating voltage of 80200 kv. The jeol jsm6400 sem and the jeol jem2010 tem instruments in the electron optics facility are no longer in service. After this, the computers should be controllable by. Jeol jem 2010 training transmission electron microscope user manual version 5. These are the only procedures you should carry out, unless you have received specific additional training. If vacuum is not good enough, contact somebody from the lme staff. Verify the vacuum in jeol pc temcon valve status window vacuum system guncamera valves v1 and v2 off black pirani gauge status pig2 and, and. Ludka is a former ufrj student who also has a doctor of science dsc from. Variety of versions is provided to adapt users purposes. The information contained in this manual is subject to change without notice. The majority of problems with tem are usually associated with poor or untrained usage. Pumps running and evac light green main panel near key switch.